INSTALLATION HINTS for the 14.4Kbps BOCAMODEM
General Hints
Please read all manuals sent with your BOCAMODEM before
installation.
Your BOCAMODEM has been initialized during factory final test for
optimum performance with the included Quick Link II fax software.
If, however, you are using another communications software package,
please use the following initialization (INIT) string:
AT&FE1V1X4&C1&D2S0=0S7=60S95=44
Quick Link II receives faxes in background mode.
Some bulletin boards and information services have problems with
data compression. If so, add %CO to the INIT string.
If you experience difficulties sending or receiving faxes, please
disable all TSR (terminate and stay resident) programs. A TSR
program is a program which remains in memory after it loads.
The easiest way to test the fax send/receive function by disabling
the TSRs is to boot your computer with a plain DOS boot disk (no
config.sys or autoexec.bat files on the boot disk). Change to the
directory containing your FAX software. Load the software and send
a fax.
If you experience a data connection difficulty with a U.S. Robotics
HST Dual Standard Modem on a BBS, the following should allow you to
connect. Set modem software to DTE speed of 9600. In command mode,
enter the following:
AT-Command Description
ATN0 Follow the S37 register
ATS37=0 Force modem to follow the DTE speed
after the next command.
Setup String for Winfax 2.0
AT&FE1V1X4&C1&D2S0=0S7=60S95=44
Connecting to another V.32bis Modem
When connecting to another v.32bis modem, use the following string:
ATN0&Q9&C1&D2&S1%E1S10=30S11=50S95=44
Set your baud rate in the dialing directory to 9600. This will let
you download at approximately 932 cps.
Connecting to an HST Dual Standard Modem
Change ATN0 to ATN1 to get a 19,200bps connection. NOTE: No V.32bis
modem other than a U.S. Robotics Dual Standard can connect to an
HST modem at greater than 2400bps.
QMODEM Setup
Modem Toggles from the QSM Menu:
XON XOFF = OFF
CTS-RTS FLOW = ON
RTS when writing = ON
FIFO DURING SHELL = OFF
LOCK DTE BAUD RATE = ON
HIGH SPEED XMIT = ON
16650 UART ENABLE = OFF
INIT IGNORES CD = ON